Professional electrical installation for pools, spas, and saunas with dedicated circuits and safety compliance.
Expert electrical installation for aquatic and wellness facilities with proper safety protection and Australian standards compliance.
Complete electrical installation for swimming pools including pumps, lighting, and heating systems.
Typical Load:
2-6kW depending on equipment
Special Requirements:
IP65 rated equipment, special earthing requirements
Dedicated electrical circuits for spas, hot tubs, and therapeutic pools with proper safety protection.
Typical Load:
3-8kW for typical spa systems
Special Requirements:
30A-50A circuits, special safety zones
Professional electrical installation for home saunas including heaters, controls, and safety systems.
Typical Load:
4-12kW for sauna heaters
Special Requirements:
High-temperature wiring, special insulation
Understanding power requirements for different pool and spa equipment to ensure proper circuit sizing.
0.75kW - 3kW
Dedicated 15A-20A circuit
Variable speed pumps save energy
4kW - 25kW
High amperage circuits
May require 3-phase power
100W - 500W
Can share with pump circuit
Low power requirement
50W - 300W total
Dedicated 10A circuit
12V LED systems preferred
3kW - 6kW
Dedicated 20A-32A circuit
Higher power for faster heating
1kW - 3kW
Dedicated 15A-20A circuit
Multiple pumps common
500W - 1.5kW
Can share circuits
Air injection systems
50W - 200W
Low voltage circuits
Smart controls available
Understanding electrical safety zones around pools and spas is critical for safe installation and compliance.
Safety Zone | Description | Max Voltage | Distance | Requirements |
---|---|---|---|---|
Zone 0 | Interior of pool/spa basin | 12V maximum | Inside the basin | Special low voltage equipment only |
Zone 1 | Area around pool edge | 12V maximum | 2m from pool edge horizontally, 2.5m vertically | IPX7 rated equipment minimum |
Zone 2 | Extended area around pool | 240V with RCD protection | 1.5m beyond Zone 1 | IPX4 rated equipment minimum |
Outside Zones | Normal electrical installation | 240V standard | Beyond all safety zones | Standard electrical requirements |
All electrical work around pools, spas, and saunas must comply with AS/NZS 3001 standards and local regulations. Our licensed electricians ensure all installations meet these critical safety requirements to protect you and your family.
We ensure all installations meet Australian electrical and building standards for maximum safety and compliance.
General electrical installation requirements
Electrical installations - Swimming pools
Pool and spa construction standards
Our systematic approach ensures safe, compliant, and reliable electrical installations for aquatic facilities.
We evaluate your pool/spa location, electrical capacity, and design the optimal circuit layout for safety and efficiency.
We handle all electrical permits, pool electrical certificates, and ensure compliance with Australian safety standards.
Professional installation of dedicated circuits, safety switches, and proper earthing with marine-grade materials.
Comprehensive electrical testing, compliance verification, and provision of electrical safety certificates.
Common questions about our electrical services
Get professional electrical installation for your pool, spa, or sauna with full safety compliance. Contact us today for expert consultation.